Skip to content

Schneider LR97D25M7 Electronic Overload Relay Formotor Tesys 5-25A 200-240V AC

Availability:
Out of stock
SKU 2500170978 | 8809755436360
Sold out
Original price £50.95 - Original price £50.95
Original price
£50.95 inc VAT
£50.95 - £50.95
Current price £50.95 inc VAT
£42.46 ex VAT
TeSys LR97D electronic overcurrent relay, 25A/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 5-21A. It provides 3 dials to adjust the protection, LOAD (5-25A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase/3-phase motors and manual/automatic reset, the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach. • TeSys LR97D electronic overcurrent relay, 25A/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 5-21A. • It provides 3 dials to adjust the protection, LOAD (5-25A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. • In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. • Settings also include selectors for 1-phase/3-phase motors and manual/automatic reset, the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signaling. • Settings can be locked by sealing the transparent cover.
DELIVERY

Free Delivery when you spend £50 inc VAT or More

Christmas Delivery Schedule

ASK A QUESTION

{"id":7984766058708,"title":"Schneider LR97D25M7 Electronic Overload Relay Formotor Tesys 5-25A 200-240V AC","handle":"schneider-electric-lr97d25m7-electronic-overload-relay-formotor-tesys-5-25a-200-240v-ac","description":"TeSys LR97D electronic overcurrent relay, 25A\/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 5-21A. It provides 3 dials to adjust the protection, LOAD (5-25A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase\/3-phase motors and manual\/automatic reset, the device has a reset button, a test\/stop button, 2 LED indicators (Run\/Trip), 2 auxiliary contacts 1NO\/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs\/Reach. • TeSys LR97D electronic overcurrent relay, 25A\/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 5-21A. • It provides 3 dials to adjust the protection, LOAD (5-25A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. • In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. • Settings also include selectors for 1-phase\/3-phase motors and manual\/automatic reset, the device has a reset button, a test\/stop button, 2 LED indicators (Run\/Trip), 2 auxiliary contacts 1NO\/NC for fault signaling. • Settings can be locked by sealing the transparent cover.","published_at":"2023-10-06T15:47:23+01:00","created_at":"2023-10-06T15:47:26+01:00","vendor":"Schneider Electric","type":"","tags":["AAEUpload061023Main","RXIN"],"price":5095,"price_min":5095,"price_max":5095,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43968139657428,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2500170978","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"Schneider LR97D25M7 Electronic Overload Relay Formotor Tesys 5-25A 200-240V AC","public_title":null,"options":["Default Title"],"price":5095,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":"8809755436360","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/81558.jpg?v=1696603646"],"featured_image":"\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/81558.jpg?v=1696603646","options":["Title"],"media":[{"alt":null,"id":32148144718036,"position":1,"preview_image":{"aspect_ratio":1.0,"height":300,"width":300,"src":"\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/81558.jpg?v=1696603646"},"aspect_ratio":1.0,"height":300,"media_type":"image","src":"\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/81558.jpg?v=1696603646","width":300}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"TeSys LR97D electronic overcurrent relay, 25A\/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 5-21A. It provides 3 dials to adjust the protection, LOAD (5-25A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase\/3-phase motors and manual\/automatic reset, the device has a reset button, a test\/stop button, 2 LED indicators (Run\/Trip), 2 auxiliary contacts 1NO\/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs\/Reach. • TeSys LR97D electronic overcurrent relay, 25A\/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 5-21A. • It provides 3 dials to adjust the protection, LOAD (5-25A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. • In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. • Settings also include selectors for 1-phase\/3-phase motors and manual\/automatic reset, the device has a reset button, a test\/stop button, 2 LED indicators (Run\/Trip), 2 auxiliary contacts 1NO\/NC for fault signaling. • Settings can be locked by sealing the transparent cover."}
Free Shipping

When you spend £50

1000s products in stock

Order by 2pm for next working day delivery*

Secure Payment

Google Pay, Apple Pay, Paypal

Great Deals

Special Offers