Skip to content

Schneider LC1D1506BD TeSys D contactor, 3p(3 NO), AC-3, <= 440V 150A 24V DC standard coi

Availability:
Out of stock
SKU 2500876433 | 3389110483017
Sold out
Original price £298.52
Original price £298.52 - Original price £298.52
Original price £298.52
Current price £52.37 inc VAT
£52.37 - £52.37
Current price £52.37 inc VAT
£43.64 ex VAT
TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 150A, 24 V DC standard coil. range: TeSys - product name: TeSys D - product or component type: contactor - device short name: LC1D - contactor application: motor control, resistive load - utilisation category: AC-1, AC-3, AC-4 - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: <= 1000 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit - [Ie] rated operational current: 150 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power kW: 100 kW at 660...690 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4, 40 kW at 220...230 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60 Hz AC-3, 75 kW at 380...400 V AC 50/60 Hz AC-3, 80 kW at 415...440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3 - motor power hp: 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947, 250 A DC for signalling circuit conforming to IEC 60947-5-1 - [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 1200 A <= 40 °C 10 s power circuit, 140 A 100 ms signalling circuit, 1400 A <= 40 °C 1 s power circuit, 250 A <= 40 °C 10 min power circuit, 580 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 250 A gG at <= 690 V coordination type 2 for power circuit, 315 A gG at <= 690 V coordination type 1 for power circuit - [Ui] rated insulation voltage: 1000 V for power circuit conforming to IEC 60947-4-1, 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for signalling circuit conforming to IEC 60947-1 - electrical durability: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V - power dissipation per pole: 13.5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: plate, rail - standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit : lugs-ring terminals - external diameter: 8 mm, power circuit : bars 1 5 x 25 mm, power circuit : lugs-ring terminals - external diameter: 25 mm - tightening torque: control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 screw : M3.5, power circuit : 12 N.m - on bars hexagonal 13 mm screw : M8, power circuit : 12 N.m - on lugs-ring terminals hexagonal 13 mm screw : M8 - operating time: 20...35 ms closing, 40...75 ms opening - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - mechanical durability: 8 Mcycles. • Designed to meet needs of demanding applications • Wide range of accessaries to satisfy different customer usage • New modern look & feel of all machines • Multiple and flexible mounting methods depending on exact need
DELIVERY

Free Delivery when you spend £50 inc VAT or More

Christmas Delivery Schedule

ASK A QUESTION

{"id":7984760750292,"title":"Schneider LC1D1506BD TeSys D contactor, 3p(3 NO), AC-3, \u003c= 440V 150A 24V DC standard coi","handle":"schneider-electric-lc1d1506bd-tesys-d-contactor-3p3-no-ac-3-440-v-150a-24-v-dc-standard-coi","description":"TeSys D contactor, 3p(3 NO), AC-3, \u0026lt;= 440 V 150A, 24 V DC standard coil. range: TeSys - product name: TeSys D - product or component type: contactor - device short name: LC1D - contactor application: motor control, resistive load - utilisation category: AC-1, AC-3, AC-4 - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: \u0026lt;= 1000 V AC 25...400 Hz for power circuit, \u0026lt;= 300 V DC for power circuit - [Ie] rated operational current: 150 A (\u0026lt;= 60 °C) at \u0026lt;= 440 V AC AC-3 for power circuit, 200 A (\u0026lt;= 60 °C) at \u0026lt;= 440 V AC AC-1 for power circuit - motor power kW: 100 kW at 660...690 V AC 50\/60 Hz AC-3, 22 kW at 400 V AC 50\/60 Hz AC-4, 40 kW at 220...230 V AC 50\/60 Hz AC-3, 75 kW at 1000 V AC 50\/60 Hz AC-3, 75 kW at 380...400 V AC 50\/60 Hz AC-3, 80 kW at 415...440 V AC 50\/60 Hz AC-3, 90 kW at 500 V AC 50\/60 Hz AC-3 - motor power hp: 100 hp at 460\/480 V AC 50\/60 Hz for 3 phases motors, 125 hp at 575\/600 V AC 50\/60 Hz for 3 phases motors, 40 hp at 200\/208 V AC 50\/60 Hz for 3 phases motors, 50 hp at 230\/240 V AC 50\/60 Hz for 3 phases motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947, 250 A DC for signalling circuit conforming to IEC 60947-5-1 - [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 1200 A \u0026lt;= 40 °C 10 s power circuit, 140 A 100 ms signalling circuit, 1400 A \u0026lt;= 40 °C 1 s power circuit, 250 A \u0026lt;= 40 °C 10 min power circuit, 580 A \u0026lt;= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 250 A gG at \u0026lt;= 690 V coordination type 2 for power circuit, 315 A gG at \u0026lt;= 690 V coordination type 1 for power circuit - [Ui] rated insulation voltage: 1000 V for power circuit conforming to IEC 60947-4-1, 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for signalling circuit conforming to IEC 60947-1 - electrical durability: 0.85 Mcycles 150 A AC-3 at Ue \u0026lt;= 440 V, 1 Mcycles 200 A AC-1 at Ue \u0026lt;= 440 V - power dissipation per pole: 13.5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: plate, rail - standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit : lugs-ring terminals - external diameter: 8 mm, power circuit : bars 1 5 x 25 mm, power circuit : lugs-ring terminals - external diameter: 25 mm - tightening torque: control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 screw : M3.5, power circuit : 12 N.m - on bars hexagonal 13 mm screw : M8, power circuit : 12 N.m - on lugs-ring terminals hexagonal 13 mm screw : M8 - operating time: 20...35 ms closing, 40...75 ms opening - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1 - mechanical durability: 8 Mcycles. • Designed to meet needs of demanding applications • Wide range of accessaries to satisfy different customer usage • New modern look \u0026amp; feel of all machines • Multiple and flexible mounting methods depending on exact need","published_at":"2023-10-06T15:38:53+01:00","created_at":"2023-10-06T15:38:56+01:00","vendor":"Schneider Electric","type":"","tags":["AAEUpload061023Main","FX","NSDec","RXIN"],"price":5237,"price_min":5237,"price_max":5237,"available":false,"price_varies":false,"compare_at_price":29852,"compare_at_price_min":29852,"compare_at_price_max":29852,"compare_at_price_varies":false,"variants":[{"id":43968129794260,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"2500876433","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"Schneider LC1D1506BD TeSys D contactor, 3p(3 NO), AC-3, \u003c= 440V 150A 24V DC standard coi","public_title":null,"options":["Default Title"],"price":5237,"weight":0,"compare_at_price":29852,"inventory_management":"shopify","barcode":"3389110483017","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/137329.jpg?v=1696603136"],"featured_image":"\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/137329.jpg?v=1696603136","options":["Title"],"media":[{"alt":null,"id":32148124139732,"position":1,"preview_image":{"aspect_ratio":1.0,"height":480,"width":480,"src":"\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/137329.jpg?v=1696603136"},"aspect_ratio":1.0,"height":480,"media_type":"image","src":"\/\/allaboutelectrics.co.uk\/cdn\/shop\/products\/137329.jpg?v=1696603136","width":480}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"TeSys D contactor, 3p(3 NO), AC-3, \u0026lt;= 440 V 150A, 24 V DC standard coil. range: TeSys - product name: TeSys D - product or component type: contactor - device short name: LC1D - contactor application: motor control, resistive load - utilisation category: AC-1, AC-3, AC-4 - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: \u0026lt;= 1000 V AC 25...400 Hz for power circuit, \u0026lt;= 300 V DC for power circuit - [Ie] rated operational current: 150 A (\u0026lt;= 60 °C) at \u0026lt;= 440 V AC AC-3 for power circuit, 200 A (\u0026lt;= 60 °C) at \u0026lt;= 440 V AC AC-1 for power circuit - motor power kW: 100 kW at 660...690 V AC 50\/60 Hz AC-3, 22 kW at 400 V AC 50\/60 Hz AC-4, 40 kW at 220...230 V AC 50\/60 Hz AC-3, 75 kW at 1000 V AC 50\/60 Hz AC-3, 75 kW at 380...400 V AC 50\/60 Hz AC-3, 80 kW at 415...440 V AC 50\/60 Hz AC-3, 90 kW at 500 V AC 50\/60 Hz AC-3 - motor power hp: 100 hp at 460\/480 V AC 50\/60 Hz for 3 phases motors, 125 hp at 575\/600 V AC 50\/60 Hz for 3 phases motors, 40 hp at 200\/208 V AC 50\/60 Hz for 3 phases motors, 50 hp at 230\/240 V AC 50\/60 Hz for 3 phases motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947, 250 A DC for signalling circuit conforming to IEC 60947-5-1 - [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 1200 A \u0026lt;= 40 °C 10 s power circuit, 140 A 100 ms signalling circuit, 1400 A \u0026lt;= 40 °C 1 s power circuit, 250 A \u0026lt;= 40 °C 10 min power circuit, 580 A \u0026lt;= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 250 A gG at \u0026lt;= 690 V coordination type 2 for power circuit, 315 A gG at \u0026lt;= 690 V coordination type 1 for power circuit - [Ui] rated insulation voltage: 1000 V for power circuit conforming to IEC 60947-4-1, 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for signalling circuit conforming to IEC 60947-1 - electrical durability: 0.85 Mcycles 150 A AC-3 at Ue \u0026lt;= 440 V, 1 Mcycles 200 A AC-1 at Ue \u0026lt;= 440 V - power dissipation per pole: 13.5 W AC-3, 24 W AC-1 - protective cover: with - mounting support: plate, rail - standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit : lugs-ring terminals - external diameter: 8 mm, power circuit : bars 1 5 x 25 mm, power circuit : lugs-ring terminals - external diameter: 25 mm - tightening torque: control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 screw : M3.5, power circuit : 12 N.m - on bars hexagonal 13 mm screw : M8, power circuit : 12 N.m - on lugs-ring terminals hexagonal 13 mm screw : M8 - operating time: 20...35 ms closing, 40...75 ms opening - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN\/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN\/ISO 13849-1 - mechanical durability: 8 Mcycles. • Designed to meet needs of demanding applications • Wide range of accessaries to satisfy different customer usage • New modern look \u0026amp; feel of all machines • Multiple and flexible mounting methods depending on exact need"}
Free Shipping

When you spend £50

1000s products in stock

Order by 2pm for next working day delivery*

Secure Payment

Google Pay, Apple Pay, Paypal

Great Deals

Special Offers